FlowCytomix™ Multiplex Kits

Multiplex Kits contain all required reagents for detection of multiple analytes in a single sample on most flow cytometers.

Reagents provided

  • Fluorescent Beads conjugated to capture antibodies
  • Biotin-conjugated detection antibody
  • PE-conjugated detection antibody
  • Reference Standard Protein
  • Streptavidin-PE, if required
  • Cytometer Setup Beads
  • Filter Plate, Plate Covers
  • Assay Buffer
  • Reagent Dilution Buffer, if required
  • The FlowCytomix Pro 2.3 (Cat. No. BMS8401FF) Software is complimentary and can be ordered at customerserv@bendermedsystems.com or downloaded at www.bendermedsystems.com/software-download

AnalyteSortingSpeciesCat. Nr.Standard RangeSensitivitySample Volume
Adhesion 6plexHumanBMS812FFsE-selectin: 4.0 - 3,000 ng/ml
sICAM-1: 5.0 - 4,000 ng/ml
sICAM-3: 11 - 8000 ng/ml
sPECAM-1: 4.0 - 3,000 ng/ml
sP-selectin: 19 - 14,000 ng/ml
sVCAM-1: 5.0 - 4,000 ng/ml
sE-selectin: 1.2 ng/ml
sICAM-1: 5.3 ng/ml
sICAM-3: 4.8 ng/ml
sPECAM-1: 0.8 ng/ml
sP-selectin: 5.7 ng/ml
sVCAM-1: 0.2 ng/ml
25 µl
Cardiovascular 6plexHumanBMS811/2FFCD40L: 55 - 40,000 pg/ml
IL-6: 27 - 20,000 pg/ml
IL-8: 13.7 - 10,000 pg/ml
MCP-1: 41 - 30,000 pg/ml
P-selectin: 3.0 - 2,000 ng/ml
t-PA: 27 - 20,000 pg/ml
CD40L: 24.3 pg/ml
IL-6: 0.4 pg/ml
IL-8: 1.1 pg/ml
MCP-1: 1.3 pg/ml
P-selectin: 1.2 ng/ml
t-PA: 4.8 pg/ml
25 µl
Chemokines 6plexMouseBMS821FF27 - 20,000 pg/ml
MCP-1: 55 - 40,000 pg/ml
GM-CSF: 12.2 pg/ml
MCP-1: 42 pg/ml
MCP-3: 1.4 pg/ml
MIP-1alpha: 1.8 pg/ml
MIP-1beta: 14.9 pg/ml
RANTES: 6.1 pg/ml
25 µl
Chemokines 6plexHumanBMS813FFG-CSF: 34.3 - 25,000 pg/ml
IL-8: 13.7 - 10,000 pg/ml
MCP-1: 41 - 30,000 pg/ml
MIG: 6.9 - 5,000 pg/ml
MIP-1alpha: 13.7 - 10,000 pg/ml
MIP-1beta: 4.1 - 3,000 pg/ml
MIP-1alpha: 1.0 pg/ml
IL-8: 2.2 pg/ml
MIP-1beta: 1.0 pg/ml
G-CSF: 3.4 pg/ml
MIG: 0.9 pg/ml
MCP-1: 2.2 pg/ml
25 µl
Cytokines 6plexRatBMS825FF27 - 20,000 pg/ml
IL-4: 3.0 - 2,000 pg/ml
rGM-CSF: 5.0 pg/ml
rIFN-gamma: 8.3 pg/ml
rIL-1alpha: 8.5 pg/ml
rIL-4: 0.3 pg/ml
rMCP-1: 0.5 pg/ml
rTNF-alpha: 4.3 pg/ml
25 µl
Obesity 9plexHumanBMS816/2FFsCD40L: 55 - 40,000 pg/ml
sICAM-1: 5 - 4,000 ng/ml
IL-6: 27 - 20,000 pg/ml
Leptin: 0.3 - 250 ng/ml
MCP-1: 41 - 30,000 pg/ml
MPO: 1.4 - 1,000 ng/ml
OPG: 27 - 20,000 pg/ml
Resistin: 55 - 40,000 pg/ml
sTNF-R (60kDa): 0.14 - 100 ng/ml
sCD40L: 12.3 pg/ml
sICAM-1: 5.3 ng/ml
IL-6: 4.4 pg/ml
Leptin: 0.05 ng/ml
MCP-1: 18.2 pg/ml
MPO: 0.02 ng/ml
OPG: 7.9 pg/ml
Resistin: 1.7 pg/ml
sTNF-R (60kDa): 0.08 ng/ml
25 µl
Th1/Th2 10plexMouseBMS820FF27 - 20,000 pg/mlmGM-CSF: 10.9 pg/ml
mIFN-gamma: 6.5 pg/ml
mIL-1alpha: 15.7 pg/ml
mIL-2: 8.8 pg/ml
mIL-4: 0.7 pg/ml
mIL-5: 4.0 pg/ml
mIL-6: 2.2 pg/ml
mIL-10: 5.4 pg/ml
mIL-17: 2.4 pg/ml
mTNF-alpha: 2.1 pg/ml
25 µl
Th1/Th2 11plexHumanBMS810FF27 - 20,000 pg/ml
hIL-8: 14 - 10,000 pg/ml
hIL-1beta: 4.2 pg/ml
IL-2: 16.4 pg/ml
hIL-4: 20.8 pg/ml
hIL-5: 1.6 pg/ml
hIL-6: 1.2 pg/ml
hIL-8: 0.5 pg/ml
hIL-10: 1.9 pg/ml
hIL-12p70: 1.5 pg/ml
hTNF-alpha: 3.2 pg/ml
hTNF-beta: 2.4 pg/ml
hIFN-gamma: 1.6 pg/ml
25 µl

Assay performance data presented was generated by Bender MedSystems, and is considered typical for a routine experiment in our laboratories (data on file at our Corporate Office in Vienna, Austria). Each laboratory using this product should establish its own performance characteristics, and these may vary from those presented on the website.